Products Center

Calibration Gas for Environmental Monitoring


Calibration Gas for Environmental Monitoring

Good air quality is the premise of sustainable development of human society, and ensure air quality in all areas of human life, it is necessary to control emissions from industry, human life. Accurate, stable and traceable calibration gas is a necessary prerequisite for the smooth operation of air quality monitoring.

Most of the reference material meeting the requirements of air quality monitoring and control standards are available, as listed below. Meanwhile other calibration gases can be customized as required by customers.

 

RM Sepc. Appliable standard
RM Cert.No. concentration Relative 
Expanded
Uncertainty
Standard NO.

RM of NO2 in N2

GBW(E)061528

10.0~1000(μmol/mol)

2%(k=2)

HJ 693-2014 Stationary source emission determination of nitrogen oxides-fixed potential by electrolysis method 

HJ 692-2014  Stationary source emission determination of nitrogen oxides-Non-dispersive infrared absorption method

BW(DT1102)

5~9.9(μmol/mol)

3%(k=2)

 

0.3~4.9(μmol/mol)

5%(k=2)

 

RM of NO in N2

GBW(E)061529

10.0~1000(μmol/mol)

2%(k=2)

HJ 693-2014 Stationary source emission determination of nitrogen oxides-fixed potential by electrolysis method

HJ 692-2014  Stationary source emission determination of nitrogen oxides-Non-dispersive infrared absorption method

JJG 801-2004 Chemiluminescent NO/NOx Analyzers 

BW(DT1101)

5~9.9(μmol/mol)

3%(k=2)

 

0.3~4.9(μmol/mol)

5%(k=2)

 

RM of CO,CO2,Propane,NO in N2O

GBW(E)062002

NO 100~499(μmol/mol)

2%(k=2)

GB 18285-2018 Limits and measurement methods for emissions from gasoline vehicles under two-speed idle conditions and short driving mode conditions 

Propane

 100~990(μmol/mol)
 CO  5000~9900(μmol/mol)

1.5%(k=2)

NO  500~5000(μmol/mol)
 propane1000~50000(μmol/mol)
CO 1%~10%
 CO 1%~15%

1%(k=2)

N2(Air)SO2

GBW(E)062157

1.00~299(μmol/mol)

2% (k=3)

JJG 551-2003-Sulfur Dioxide Gas Detectors 

HJ 57-2017 Stationary source emission-determination of sulfur dioxide -Fixed potential electrolysis method 

HJ 629-2011 Stationary source emission-determination of sulphur dioxide-Non-dispersive infrared absorption method 

300~3000(μmol/mol)

1%(k=3)

HJ/T 46-1999 Technical conditions of detector of sulphur dioxide concentration for constant potential electrolysis method 

BW(DT0130)

0.2~0.99(μmol/mol)

4%(k=2)

 

N2(Air)H2S

GBW(E)062156

1.00~3000(μmol/mol)

2% (k=3)

JJG 695-2003-Sulfur Hydrogen Gas detectors 

0.100~0.999(μmol/mol)

3 %(k=3)

MT 1084 2008 Coal mine hydrogen sulfide alarm detector 

1.00~49.9(μmol/mol)

2 %(k=3)

GB/T 14678-93 Air quality-Determination of sulfuretted hydrogen, methyl sulfhydryl, dimethyl sulfide and dimethyl disulfide -Gas chromatography 

50.0~999(μmol/mol)

1% (k=3)

BW(DT0131)

0.05~0.099(μmol/mol)

10%(k=3)

 

RM of CH4 in Air

GBW(E)060678

1.00~4999.9(μmol/mol)

2%(k=2)

HJ 1012-2018 Ambient air and stationary source emission -specifications and test procedures for hydrocarbons, methane and nonmethane hydrocarbons portable total monitoring instrument. 

5000~30000  (μmol/mol)

1%(k=2)

HJ 1013-2018 specifications and test procedures for nonmethane hydrocarbons continuous emission monitoring system in stationary sources 

HJ 38-2017 Stationary source emission-determination of total hydrocarbons, methane and nonmethane hydrocarbons-Gas chromatography 

HJ 604-2017 Ambient air-determination of total hydrocarbons, methane and nonmethane hydrocarbons-direct injection/Gas chromatography 

Rm of Propane in Air

GBW(E)062248

1.00~100(μmol/mol)

2%(k=2)

HJ 1013-2018 Specifications and test procedures for nonmethane hydrocarbons continuous emission monitoring system in stationary sources  

100~10000(μmol/mol)

1%(k=2)

RM of propane in N2

GBW(E)062249

1.00~100(μmol/mol)

2%(k=2)

100~10000(μmol/mol)

1%(k=2)

RM of CO in air

GBW(E)062250

5.00  ~499(μmol/mol)

2%(k=2)

GB/T  18204.2-2014  Examination methods for public places-part 2: chemical pollutants 

500~50000(μmol/mol)

1%(k=2)

GB 9801-88 Air quality-Determination of carbon monoxide- Non-dispersive infrared spectrometry 

HJ 965-2018 Ambient air-Automatic determination of carbon monoxide -Non-dispersive infrared spectrometry method 

RM of CO in N2

GBW(E)062251

5.00  ~499(μmol/mol)

2%(k=2)

HJ 973-2018 Stationary source emission-Determination of carbon monoxide-Fixed potential by electrolysis method  

500~50000(μmol/mol)

1%(k=2)

HJ/T 44-1999 Stationary source emission-Determination of carbon monoxide-Non-dispersive infrared absorption method 

RM of CO2 in N2 

GBW(E)062587

2.00~499(μmol/mol)

2%(k=2)

GB/T  18204.2-2014 Examination methods for public places-Part 2: chemical pollutants 

GBW(E)062588

500~10000(μmol/mol)

1%(k=2)

RM of CO2 in air 

GBW(E)062589

2.00~499(μmol/mol)

2%(k=2)

HJ 870-2017 Stationary source emission-Determination of carbon dioxide -Non-dispersive infrared absorption method 

GBW(E)062590

500~10000(μmol/mol)

1%(k=2)

RM of NH3 in air 

GBW(E)062288

5.00  ~4990(μmol/mol)

2%(k=2)

JJG 1105-2015 Ammonia Gas Detectors 

5000~50000(μmol/mol)

1%(k=2)

RM of NH3 in N2 

GBW(E)062289

5.00  ~4990(μmol/mol)

2%(k=2)

5000~50000(μmol/mol)

1%(k=2)

BW(DT0133)

1~4.99(μmol/mol)

3%(k=2)

 

RM of Cl2 in air

GBW(E)062290

5.00~100(μmol/mol)

2%(k=2)

JJF 1433-2013 Calibration Specification for chlorine alarm detectors 

RM of cl2 in air 

GBW(E)062291

5.00~100(μmol/mol)

2%(k=2)

BW(DT1201)

2~4.99(μmol/mol)

3%(k=2)

RM of HCL in air质

GBW(E)062378

5.00~1000(μmol/mol)

2%(k=2)

 

RM of HCL in N2

GBW(E)062379

5.00~1000(μmol/mol)

2%(k=2)

BW(DT0127)

3.00~4.99(μmol/mol)

3%(k=2)

RM of HF in N2/air

BW(DT1202)

3~1000(μmol/mol)

3%(k=2)

 

RM of O2 in N2 

GBW(E)062593

5%~30%

1%(k=3)

JJG 365-2009 Electrochemical Oxygen Meter 

RM of isobutene in N2

GBW(E)062583

1.00~499(μmol/mol)

2%(k=2)

JJG(yue)035-2017 Benzene Gas Detectors 

GBW(E)062584

500~10000(μmol/mol)

1%(k=2)